HACMP for AIX
PowerVM Enterprise Edition
IBM Management Edition for AIX
Workload Partition Manager for AIX
第1题:
A customer has a p650 on order and plans to put it in a current OEM rack. They are concerned that the p650 power supply may demand more current than the OEM PDU can provide. Which planning guide specification would provide the necessary requirements?()
第2题:
There is a power outage and all servers are shut down properly by the uninterruptible power supply(UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors,16GB of memory, and a RAID 5 array with 10 drives. Which of the following is the MOST likely cause?()
第3题:
Which feature of the IBM p5 servers enables customers to be confident that data within two distinct partitions on the server will be isolated?()
第4题:
A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700. They would like to upgrade and plan for 40 TB capacity. The customer needs to move to a more scalable storage system to include all servers.Which of the following would be most appropriate to ask first?()
第5题:
A customer has two locations that host their pSeries servers. Traffic is being routed through the public Internet. The customer needs to exchange confidential financial data between the servers. Which of the following solutions should the pSeries technical specialist propose to the customer to secure the data?()
第6题:
A customer requires two 12X loops on their new POWER7 system. What is the smallest system that will support two loops?()
第7题:
A retail customer is looking at ways to reduce power requirements. They are considering deploying two hundred IBM HS22 blades running Red Hat Linux in the IBM BladeCenter E chassis. The customer has already chosen Intel L5640 CPUs to reduce power. Which on-board storage option allows the customer to reduce power consumption of each blade?()
第8题:
A customer is configuring Live Partition Mobility on two POWER6-based servers, Which of the following is required on both the source and the destination VIO servers for the mobile partition to participate in an active partition migration?()
第9题:
An IT director needs to deploy 3 partitions, each using dedicated internal boot disk. Which system will support the customer requirement using the least amount of rack space?()
第10题:
IBM Director connection
Dynamic LPAR Resource Manager (DLRM)
Barrier Synchronization Register Device (BSR)
Virtual Asynchronous Services Interface (VASI)
第11题:
A
B
C
D
第12题:
AIX Basic Edition
AIX Express Edition
AIX Standard Edition
AIX Enterprise Edition
第13题:
A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation. What multipathing driver is required to build a redundant solution?()
第14题:
retail company plans to consolidate 180 existing dual processor Xeon servers, all running a web server application on Windows Server 2003. They are planning consolidating to a single x3950 X5 running vSphere.Which of the following should be discussed with this customer? ()
第15题:
A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers. What configuration setting does the storage specialist need to highlight?()
第16题:
A customer recently acquired two Power servers and plans to implement AIX 6.1 and Live Application Mobility. What other product is required to accomplish this objective? ()
第17题:
A customer has requested five rack mounted servers, and a rack. They want redundant power connections. Which of the following is required to meet these requirements?()
第18题:
A customer is buying 10 new Power 720 servers and will integrate them into their existing data center which also has two Power 595s and five Power 750s, taking the total number of systems to 17. All currently installed systems are managed by a single HMC.All the machines will have dual VIO Servers for redundancy, and 10 client LPARs. How can they manage the new machines for the least cost?()
第19题:
A retail company plans to consolidate 180 existing dual processor Xeon servers, all running a web server application on Windows Server 2003. They are planning consolidating to a single x3950 X5 running vSphere. Which of the following should be discussed with this customer?()
第20题:
A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700. They would like to upgrade and plan for 40 TB capacity. The customer needs to move to a more scalable storage system to include all servers. Which of the following would be most appropriate to ask first?()
第21题:
HACMP for AIX
PowerVM Enterprise Edition
IBM Management Edition for AIX
Workload Partition Manager for AIX
第22题:
Is the web content static or dynamic information
Consider two servers for redundancy and failover
What is the average CPU utilization of the existing web servers
Will the servers need a SCSI or Fibre Channel storage solution
第23题:
A DCE domain
A Kerberos domain
A PPP tunnel between the servers
An IPSEC tunnel between the servers
第24题:
Explain to the customer that they need an additional HMC for the POWER5 system.
Obtain a PO from the customer to purchase additional serial connections to the HMC.
Obtain a PO from the customer to purchase additional Ethernet connections to the HMC.
Explain to the customer that they need a firmware update on the HMC to support both POWER4 and POWER5.