niusouti.com

单选题Company.com recently experienced an unanticipated system outage when the VIO server was upgraded. The current p5-570 has six Micro-Partitions and a VIO server partition. How can a similar outage be avoided in the future?()A Use DLPAR to avoid an outage

题目
单选题
Company.com recently experienced an unanticipated system outage when the VIO server was upgraded. The current p5-570 has six Micro-Partitions and a VIO server partition. How can a similar outage be avoided in the future?()
A

Use DLPAR to avoid an outage.

B

Deploy a redundant VIO server in the POWER5 system.

C

Add additional Host Bus Adapters and Network adapters to the VIO server.

D

Implement a standby server and move all partitions to it before applying future updates.


相似考题
更多“单选题Company.com recently experienced an unanticipated system outage when the VIO server was upgraded. The current p5-570 has six Micro-Partitions and a VIO server partition. How can a similar outage be avoided in the future?()A Use DLPAR to avoid an outage”相关问题
  • 第1题:

    A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()

    • A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.
    • B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.
    • C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.
    • D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

    正确答案:D

  • 第2题:

    Which action enables an administrator to make a VIO Server automatically activate when the physical machine is powered on?()  

    • A、Ensure the /etc/auto_start file exists on the VIos
    • B、Ensure the ’cfgdev -a boot=yes’ command has been executed.
    • C、Select the ’Automatically start when the managed system is powered on’ option within the vio Server lpar profile.
    • D、Add the VIO Server to the ’Automatically start when the managed system is powered on’ field on the managed System properties.

    正确答案:C

  • 第3题:

    A customer uses third party storage and would like to connect it to a Virtual IO server on a Power 550.  How can the third party storage device drivers be installed? ()

    • A、 Use SUMA to obtain the drivers.
    • B、 Use smitty install on the client partitions.
    • C、 Use oem_setup_env environment in the VIO server.
    • D、 Use cfgmgr to configure the devices within the client partition.

    正确答案:C

  • 第4题:

    Company.com recently experienced an unanticipated system outage when the VIO server was upgraded. The current p5-570 has six Micro-Partitions and a VIO server partition. How can a similar outage be avoided in the future?()

    • A、Use DLPAR to avoid an outage.
    • B、Deploy a redundant VIO server in the POWER5 system.
    • C、Add additional Host Bus Adapters and Network adapters to the VIO server.
    • D、Implement a standby server and move all partitions to it before applying future updates.

    正确答案:B

  • 第5题:

    Company.com is ordering a new p5-570 and planning for the option of using Capacity on  Demand to activate additional resources in the future. Which of the following is a prerequisite to support the addition of CPUs or memory without an outage?()

    • A、Use Micro-Partitioning
    • B、Configure a Virtual I/O Server
    • C、Configure dynamic logical partitions
    • D、Activate Advanced POWER Virtualization

    正确答案:C

  • 第6题:

    单选题
    Company.com has a database application and a Web server application running on the same p5-570 server in a single partition. Recently there have been a number of instances where the increased load on the database server has impacted the performance of the Web server. What can the technical specialist recommend to keep the database application from impacting the performance of the Web server?()
    A

    Create a VLAN between the web server and database server.

    B

    Purchase APV and install the VIOS.

    C

    Increase the priority of the Web server.

    D

    Create separate LPARs for Web and database workloads.


    正确答案: D
    解析: 暂无解析

  • 第7题:

    单选题
    Company.com recently experienced an unanticipated system outage when the VIO server was upgraded. The current p5-570 has six Micro-Partitions and a VIO server partition. How can a similar outage be avoided in the future?()
    A

    Use DLPAR to avoid an outage.

    B

    Deploy a redundant VIO server in the POWER5 system.

    C

    Add additional Host Bus Adapters and Network adapters to the VIO server.

    D

    Implement a standby server and move all partitions to it before applying future updates.


    正确答案: B
    解析: 暂无解析

  • 第8题:

    单选题
    A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()
    A

    A VIO server requires a dedicated LHEA port.

    B

    There is a limit of 32 LPARs per virtual LAN.

    C

    Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.

    D

    Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.


    正确答案: A
    解析: 暂无解析

  • 第9题:

    单选题
    The administrator wants to backup the existing VIO server software and its current configuration before applying an update.  What command will the administrator use to backup the VIO server software so that the backup can be restored from a Network Installation Manager (NIM) server or a Hardware Management Console (HMC)?()
    A

     mksysb -t vio /mountpoint

    B

     backupios -file /mountpoint

    C

     mksysb -i /mountpoint/vio.mksysb

    D

     backupios -mksysb -file /mountpoint/vio.mksysb


    正确答案: B
    解析: 暂无解析

  • 第10题:

    单选题
    Company.com has an EMC disk array and would like to connect it to a Virtual I/O Server on a pSeries p5-520.  How can the EMC device drivers be installed?()
    A

    Use smitty install on the client partitions.

    B

    Use padmin command in the VIO Server.

    C

    Use the oem_setup_env environment in the VIO Server.

    D

    Use cfgmgr to detect/configure the devices within the client AIX partition.


    正确答案: C
    解析: 暂无解析

  • 第11题:

    单选题
    While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()
    A

    NPIV andvSCSI both require multipathing in VIO Server only.

    B

    NPIV requiresmultipathing software on client LPARs, vSCSI requires multipathing software on VIO Server.

    C

    NPIV requiresmultipathing software on VIO Server, vSCSI requires multipathing software on client LPARs.

    D

    NPIV requiresmultipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing   software on VIO Server and MPIO on client LPARs.


    正确答案: A
    解析: 暂无解析

  • 第12题:

    单选题
    A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()
    A

     Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.

    B

     Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.

    C

     Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.

    D

     Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.


    正确答案: D
    解析: 暂无解析

  • 第13题:

    An administrator has recently added a VLAN to the VIO server and wants to update the documentation. Which command displays the current VIO server VLAN configuration?()

    • A、lsmap -all
    • B、lsmap -net
    • C、lsmap -ent
    • D、lsmap -vlan

    正确答案:B

  • 第14题:

    Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()

    • A、Allocate the CD to the VIO Server and NFS export the CD to the user LPARs
    • B、Allocate the CD to one of the user LPARs and config the VIO Server to NFS import it
    • C、Allocate the CD to the VIO Server and the LPARs will share it as a Virtual SCSI device
    • D、Allocate the CD to one of the user LPARs and NFS export it to the remaining user LPARs

    正确答案:D

  • 第15题:

    Company.com has a p5-570 with an application running on each of three Micro-Partitions. The disk I/O is shared through a VIO server. A technical specialist has been asked to upgrade the VIO  server. Which of the following procedures should be taken to maintain the integrity of the partitions?()

    • A、Shut down all client partitions before updating the VIO server.
    • B、Disconnect the client partitions from any IP networks before updating the VIO server.
    • C、Update the client partitions to the latest OS maintenance level before updating the VIO Server.
    • D、Update the VIO server while the partitions are running, but reboot each client partition at a convenient time after the update.

    正确答案:A

  • 第16题:

    A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()

    • A、A VIO server requires a dedicated LHEA port.
    • B、There is a limit of 32 LPARs per virtual LAN.
    • C、Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.
    • D、Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

    正确答案:A

  • 第17题:

    单选题
    Company.com has a p5-570 with an application running on each of three Micro-Partitions. The disk I/O is shared through a VIO server. A technical specialist has been asked to upgrade the VIO  server. Which of the following procedures should be taken to maintain the integrity of the partitions?()
    A

    Shut down all client partitions before updating the VIO server.

    B

    Disconnect the client partitions from any IP networks before updating the VIO server.

    C

    Update the client partitions to the latest OS maintenance level before updating the VIO Server.

    D

    Update the VIO server while the partitions are running, but reboot each client partition at a convenient time after the update.


    正确答案: C
    解析: 暂无解析

  • 第18题:

    单选题
    Company.com recently experienced an unanticipated system outage when the VIO server was upgraded. The current p5-570 has six Micro-Partitions and a VIO server partition. How can a similar outage be avoided in the future?()
    A

    Use DLPAR to avoid an outage.

    B

    Deploy a redundant VIO server in the POWER5 system.

    C

    Add additional Host Bus Adapters and Network adapters to the VIO server.

    D

    Implement a standby server and move all partitions to it before applying future updates.


    正确答案: D
    解析: 暂无解析

  • 第19题:

    单选题
    A customer uses third party storage and would like to connect it to a Virtual IO server on a Power 550.  How can the third party storage device drivers be installed? ()
    A

     Use SUMA to obtain the drivers.

    B

     Use smitty install on the client partitions.

    C

     Use oem_setup_env environment in the VIO server.

    D

     Use cfgmgr to configure the devices within the client partition.


    正确答案: A
    解析: 暂无解析

  • 第20题:

    单选题
    You have successfully sold and installed your customer’s System x solution. Sometimes, the overall succeed of a sale depends on how well you have trained your customer to support their new hardware. Please consider the following tools. Which one would be the best for protectively determining a server outage, and contacting the system administrator about the outage?()
    A

    CDAT

    B

    Configuration and Options Guide (COG)

    C

    Physical Alarm Sounding in Data Center

    D

    IBM Systems Director


    正确答案: A
    解析: 暂无解析

  • 第21题:

    单选题
    An administrator has recently added a VLAN to the VIO server and wants to update the documentation. Which command displays the current VIO server VLAN configuration?()
    A

    lsmap -all

    B

    lsmap -net

    C

    lsmap -ent

    D

    lsmap -vlan


    正确答案: A
    解析: 暂无解析

  • 第22题:

    单选题
    A file server is setup in a RAID 5 configuration.Recently there was a power failure in the server room while a user was transferring a document from one drive on the server to another drive on the same server.Unfortunately their UPS was in repair during this outage, and the file is now corrupt.Which of the following can be done to prevent this situation in the future?()
    A

    Increase the memory on the server.

    B

    Reconfigure drives to a RAID 0+1.

    C

    Install a battery backed write cache module in the system.

    D

    Instruct the user to save to the local system instead of to the server.


    正确答案: C
    解析: 暂无解析

  • 第23题:

    单选题
    Which action enables an administrator to make a VIO Server automatically activate when the physical machine is powered on?()
    A

    Ensure the /etc/auto_start file exists on the VIos

    B

    Ensure the ’cfgdev -a boot=yes’ command has been executed.

    C

    Select the ’Automatically start when the managed system is powered on’ option within the vio Server lpar profile.

    D

    Add the VIO Server to the ’Automatically start when the managed system is powered on’ field on the managed System properties.


    正确答案: C
    解析: 暂无解析

  • 第24题:

    单选题
    Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()
    A

    Allocate the CD to the VIO Server and NFS export the CD to the user LPARs

    B

    Allocate the CD to one of the user LPARs and config the VIO Server to NFS import it

    C

    Allocate the CD to the VIO Server and the LPARs will share it as a Virtual SCSI device

    D

    Allocate the CD to one of the user LPARs and NFS export it to the remaining user LPARs


    正确答案: A
    解析: 暂无解析