niusouti.com

单选题A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()

题目
单选题
A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()
A

A VIO server requires a dedicated LHEA port.

B

There is a limit of 32 LPARs per virtual LAN.

C

Two VIO servers will be required. A single VIO server can only provide virtual storage or Virtual Ethernet.

D

Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.


相似考题
更多“单选题A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()”相关问题
  • 第1题:

    Companycom has a p5 590 that has their production LPAR, their Tivoli Storage Manager (TSM) LPAR, and several other LPARs. What method would provide connectivity between the production LPAR, and the TSM LPAR, but be isolated from the other LPARs in the system without utilizing a Virtual IO Server or physical adapter resources?()

    • A、Use shared memory and semaphores to transfer the data to the TSM LPAR
    • B、Provide gigabit Ethernet adapters in each LPAR and run a crossover cable
    • C、Create a Virtual Ethernet between the production server and the TSM LPARs
    • D、Create a Virtual Ethernet between the TSM server LPAR and the non-production LPARs

    正确答案:C

  • 第2题:

    While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()

    • A、NPIV and vSCSI both require multipathing in VIO Server only. 
    • B、NPIV requires multipathing software on client LPARs, vSCSI requires multipathing software on VIO Server. 
    • C、NPIV requires multipathing software on VIO Server, vSCSI requires multipathing software on client LPARs. 
    • D、NPIV requires multipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.

    正确答案:B

  • 第3题:

    A customer is planning to buy a two enclosure Power 770, and will implement 4 LPARs with the following requirements:Each LPAR must have a private, dedicated connection to the network.The adapter for this network connection must be hot-swappable.The customer wants to minimize the number of I/O slots used. Which of the following fulfills the customer requirements?()

    • A、Two dual-port PCIe adapters
    • B、A four-port PCIe Ethernet adapter
    • C、Four separate PCIe Ethernet adapters
    • D、Two embedded Integrated Virtual Ethernet adapters (IVE)

    正确答案:C

  • 第4题:

    Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()

    • A、Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.
    • B、Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.
    • C、Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.
    • D、Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

    正确答案:C

  • 第5题:

    Which are the two main uses of a VIO server?() 

    • A、Virtualize network and memory to LPARs.
    • B、Virtualize network and storage to LPARs.
    • C、Virtualize memory and processors to LPARs.
    • D、Virtualize storage and processors to LPARs.

    正确答案:B

  • 第6题:

    A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()

    • A、A VIO server requires a dedicated LHEA port.
    • B、There is a limit of 32 LPARs per virtual LAN.
    • C、Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.
    • D、Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

    正确答案:A

  • 第7题:

    单选题
    A customer is planning to buy a two enclosure Power 770, and will implement 4 LPARs with the following requirements:Each LPAR must have a private, dedicated connection to the network.The adapter for this network connection must be hot-swappable.The customer wants to minimize the number of I/O slots used. Which of the following fulfills the customer requirements?()
    A

    Two dual-port PCIe adapters

    B

    A four-port PCIe Ethernet adapter

    C

    Four separate PCIe Ethernet adapters

    D

    Two embedded Integrated Virtual Ethernet adapters (IVE)


    正确答案: A
    解析: 暂无解析

  • 第8题:

    单选题
    A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()
    A

    1

    B

    7

    C

    15

    D

    31


    正确答案: B
    解析: 暂无解析

  • 第9题:

    单选题
    A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()
    A

    Implement PowerHA SystemMirror on both VIO servers.

    B

    Configure Etherchannel between the client LPARs and the two VIO servers.

    C

    Configure Network Interface Backup between the two VIO servers and use each VIO server to access the  network.

    D

    Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.


    正确答案: A
    解析: 暂无解析

  • 第10题:

    单选题
    A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()
    A

    ImplementPowerHA SystemMirror on both VIO servers.

    B

    ConfigureEtherchannel between the client LPARs and the two VIO servers

    C

    Configure Network Interface Backup between the two VIO servers and use each VIO server to access the  network.

    D

    Implement Shared Ethernet Adapter failover and have all client partitions access the network through the   shared adapters.


    正确答案: D
    解析: 暂无解析

  • 第11题:

    单选题
    Companycom has a p5 590 that has their production LPAR, their Tivoli Storage Manager (TSM) LPAR, and several other LPARs. What method would provide connectivity between the production LPAR, and the TSM LPAR, but be isolated from the other LPARs in the system without utilizing a Virtual IO Server or physical adapter resources?()
    A

    Use shared memory and semaphores to transfer the data to the TSM LPAR

    B

    Provide gigabit Ethernet adapters in each LPAR and run a crossover cable

    C

    Create a Virtual Ethernet between the production server and the TSM LPARs

    D

    Create a Virtual Ethernet between the TSM server LPAR and the non-production LPARs


    正确答案: D
    解析: 暂无解析

  • 第12题:

    单选题
    Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()
    A

    Allocate the CD to the VIO Server and NFS export the CD to the user LPARs

    B

    Allocate the CD to one of the user LPARs and config the VIO Server to NFS import it

    C

    Allocate the CD to the VIO Server and the LPARs will share it as a Virtual SCSI device

    D

    Allocate the CD to one of the user LPARs and NFS export it to the remaining user LPARs


    正确答案: A
    解析: 暂无解析

  • 第13题:

    A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()

    • A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.
    • B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.
    • C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.
    • D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

    正确答案:D

  • 第14题:

    A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()

    • A、1
    • B、7
    • C、15
    • D、31

    正确答案:D

  • 第15题:

    Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()

    • A、Allocate the CD to the VIO Server and NFS export the CD to the user LPARs
    • B、Allocate the CD to one of the user LPARs and config the VIO Server to NFS import it
    • C、Allocate the CD to the VIO Server and the LPARs will share it as a Virtual SCSI device
    • D、Allocate the CD to one of the user LPARs and NFS export it to the remaining user LPARs

    正确答案:D

  • 第16题:

    A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down.  Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()

    • A、Implement PowerHA SystemMirror on both VIO servers.
    • B、Configure Etherchannel between the client LPARs and the two VIO servers
    • C、Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
    • D、Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

    正确答案:C

  • 第17题:

    The administrator of a Power 595 server is required to concurrently host LPARs for two different customers. Both customers’ LPARs have the same VLAN ID and subnet range, but their traffic must be isolated from each other.  Which feature within the system would provide this functionality?()

    • A、 802.1Q
    • B、 Virtual switch
    • C、 Logical Host Ethernet (LHE) Adapter
    • D、 Shared Ethernet Adapter (SEA) Trunking

    正确答案:B

  • 第18题:

    单选题
    While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()
    A

    NPIV and vSCSI both require multipathing in VIO Server only. 

    B

    NPIV requires multipathing software on client LPARs, vSCSI requires multipathing software on VIO Server. 

    C

    NPIV requires multipathing software on VIO Server, vSCSI requires multipathing software on client LPARs. 

    D

    NPIV requires multipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.


    正确答案: B
    解析: 暂无解析

  • 第19题:

    单选题
    Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()
    A

    Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.

    B

    Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.

    C

    Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.

    D

    Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.


    正确答案: A
    解析: 暂无解析

  • 第20题:

    单选题
    The administrator of a Power 595 server is required to concurrently host LPARs for two different customers. Both customers’ LPARs have the same VLAN ID and subnet range, but their traffic must be isolated from each other.  Which feature within the system would provide this functionality?()
    A

     802.1Q

    B

     Virtual switch

    C

     Logical Host Ethernet (LHE) Adapter

    D

     Shared Ethernet Adapter (SEA) Trunking


    正确答案: A
    解析: 暂无解析

  • 第21题:

    单选题
    A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()
    A

    A VIO server requires a dedicated LHEA port.

    B

    There is a limit of 32 LPARs per virtual LAN.

    C

    Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.

    D

    Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.


    正确答案: A
    解析: 暂无解析

  • 第22题:

    单选题
    Which are the two main uses of a VIO server?()
    A

    Virtualize network and memory to LPARs.

    B

    Virtualize network and storage to LPARs.

    C

    Virtualize memory and processors to LPARs.

    D

    Virtualize storage and processors to LPARs.


    正确答案: A
    解析: 暂无解析

  • 第23题:

    单选题
    A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()
    A

     Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.

    B

     Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.

    C

     Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.

    D

     Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.


    正确答案: D
    解析: 暂无解析

  • 第24题:

    单选题
    When doing capacity planning for the Virtual I/O Server,what is the most important  consideration?()
    A

    The I/O workload needs of the client LPARs

    B

    The processing requirements of the client LPARs

    C

    The memory requirements of the client LPARs

    D

    The virtual Ethernet requirements between client LPARs


    正确答案: A
    解析: 暂无解析