第1题:
A banking customer orders three IBM BladeCenter E chassis and thirty-four HS22 blades. Theustomer wants to fully populate the chassis with blades where possible. Which of the following is the minimum number of power cables required to provide redundancy? ()
第2题:
A customer is interested in reducing energy consumption and infrastructure consolidation for space. The customer needs a maximum of 14 servers in 7U rack. Which IBM BladeCenter Chassis should be recommended? ()
第3题:
A customer needs to add three JS22 blade servers. The customer currently has three HS21 Blade servers and one LS41 4-socket Blade Server. Based upon this information, what additional items does the customer need to purchase? ()
第4题:
A customer has the following equipment installed in their data center: (1)an IBM BladeCenter H chassis (2)two power supplies (3)six HS22V blades (4)three Nortel 1/10 GB ESMs The retail customer purchased a new HX5 with MAX5. Which of the following must be added to install the HX5 with MAX5?()
第5题:
A banking customer deployed an IBM BladeCenter chassis with one Brocade 8Gb SAN switch module. The customer requires an 8Gb uplink or higher. Which configuration will meet this request of the following?()
第6题:
A University customer has a BladeCenter H fully populated with LS21 Blades, a single AMM, and four power modules. The BladeCenter has been running flawlessly for three months. One day an administrator discovers that they cannot view video on blades 9-12 either locally or remotely even though they still appear to be running. The video works on all of the other blades. Which of the following is the cause of the video problem?()
第7题:
An IBM BladeCenter H chassis for the JS22 Blade servers
A concurrent KVM daughter card
A pair of IBM BladeCenter Power Supplies
A second Management Module
第8题:
The Blades must use the same CIOv and CFFh expansion adapter types.
Two physical BladeCenter H chassis will be required. One for the POWER Blades, the other for the x86 Blades.
The x86 Blades and POWER Blades may use different expansion adapters provided the POWER Blades are in bays 1-7 and the x86 Blades are in slots 8-14.
The x86 Blades and POWER Blades may use different expansion adapters, provided the corresponding I/O modules to Blade midplane connections are configured in the Advanced Management Module (AMM).
第9题:
Support for10Gb internal network
Support for SSD
Support for integrated disk drives
Support for8Gb FC Switch Modules
第10题:
Brocade Enterprise 20-port 8Gb SAN switch module
Brocade 20-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter share
Brocade Enterprise 10-port 8Gb SAN switch module
Brocade 10-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter
第11题:
6
8
10
12
第12题:
4
3
2
8
第13题:
Your customer has converted from traditional servers to BladeCenter technology and has a requirement for an RSA adapter on a new BladeCenter server. Which of the following options would you use? ()
第14题:
A banking customer deployed an IBM BladeCenter chassis with one Brocade 8Gb SAN switch module. The customer requires an 8Gb uplink or higher. Which configuration will meet this request?()
第15题:
A customers has asked you to investigate their current x86 server environment to determinate if they can achieve a reduction in power and rack consumption. They plan to implement VMware and the local storage shared. Which of the following consolidation proposals meets these needs?()
第16题:
A customer is considering BladeCenter H and S chassis. Which of the following is a reason to implement BladeCenter H?()
第17题:
A customer has a BladeCenter E installed and plans to migrate their current Blades to the BladeCenter H. What options will migrate from the BladeCenter E to the BladeCenter H chassis? ()
第18题:
A power module has failed and there is not enough power to see video on all blades.
MUX 3 on theBladeCenter backplane has failed.
A firmware update is required on the AMM.
A second AMM is required to view video on blades 9-14.
第19题:
Two additional power supplies
Fibre Channel (FC) switches and SAN storage
A Nortel 1/10 GB ESM
SSD for the HX5
第20题:
Remote Supervisor Adapter II (RSA II Slimline)
Management Module, which comes standard on the BladeCenter
Acoustic Attenuation Module
Ethernet NICs
第21题:
4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server
Cisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module
Fibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module
Cisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server
第22题:
Brocade Enterprise 20-port 8Gb SAN switch module
Brocade 20-port8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter
Brocade Enterprise 10-port 8Gb SAN switch module
Brocade 10-port8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter
第23题:
12
10
8
6
第24题:
SAN Switch modules
Blowers
Power supplies
Battery backup units