perform a Disk Magic study
review eConfig with a technical specialist
confirm that the customer has enough ports available in the SAN infrastructure
submit configuration to IBM System Storage Interoperability Center for validation
第1题:
Which IBM resource should be used to validate the results from a Disk Magic study PRIOR topresenting the final storage solution and pricing to a customer?()
第2题:
A customer is interested in purchasing a new IBM System Storage DS8000 solution to consolidateolder ESS and F20 storage systems. What should be done first, prior to final proposaldevelopment?()
第3题:
A customer asks for the thermal load (BTU/hr) to determine whether their existing cooling system will support the IBM System Storage DS8000. Where can the sales representative find this information()
第4题:
A small bio-tech company is interested in implementing an IBM System Storage solution. Which ofthe following tools can be used to help justify the cost of our solution to a customer?()
第5题:
A customer has two data centers, 500 kilometers apart. The customer requests a proposal for new storage subsystems and a disaster recovery solution that provides consistent data in the event of a disaster at the local site. Which IBM System Storage DS8000 solution should the storage specialist propose to the client()
第6题:
What information, in addition to model number and serial number, is necessary to perform featureactivation for the IBM System Storage DS8000?()
第7题:
verify configuration
conduct pre-install TDA
complete physical planning
verify the solution meets requirements
第8题:
TCOnow
Disk Magic
Capacity Magic
System Storage Productivity Center (SSPC)
第9题:
perform a Disk Magic study
review eConfig with a technical specialist
confirm that the customer has enough ports available in the SAN infrastructure
submit configuration to IBM System Storage Interoperability Center for validation
第10题:
TDA
Capacity Magic
business case review
SAN configuration review
第11题:
add an expansion frame with additionalFibre Channel ports
increase the amount of storage by 20 TB
conduct a Disk Magic study to identify the source of the performance issue
add additionalFibre Channel ports to the existing DS8700
第12题:
initiate a Disk Magic study
initiate a Capacity Magic study
runiometer on the current environment
utilize the IBM Disk capacity planner toolkit
第13题:
An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN that is now configured with an EMC Symmetrix subsystem disk. The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()
第14题:
A storage specialist is proposing a solution consisting of an IBM System Storage TS3200 TapeLibrary and a SAN Volume Controller, both of which are being added to a customer’s existing SANenvironment for the first time. Which of the following should be completed before the proposal ispresented to the customer?()
第15题:
A customer has a wide range of IBM enterprise disk systems and wants to manage copy services functions. Which of the products should the storage specialist recommend to this customer()
第16题:
A customer has installed an IBM System Storage DS8700 with 20 TB of storage, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues since they have added new workloads. The customer asks the storage specialist for guidance. Which of the following actions should be recommended as a first step?()
第17题:
A customer is purchasing an IBM System Storage DS8700. What is the most important first step for the installation?()
第18题:
The customer has an older storage array and is looking to migrate data that currently exists onover 100 73 GB FC drives to a new IBM System Storage DS5020. The customer states that theyhave only 3 TB of data and wants to consolidate on to fewer higher capacity drives. There are sixapplication servers running multiple applications and operating systems utilizing the storagesystem. What would be the next step to accurately identify the new storage configuration?()
第19题:
TS3500 Redbook
TS3500 Operators Manual
Solution Assurance Product Review (SAPR) Guide
TS3500 Product Installation and Planning Guide
第20题:
IBM System Storage DS8000: Host Systems Attachment Guide
DS8000 Interoperability Matrix
IBM System Storage DS8000: Introduction and Planning Guide
IBM System Storage Solution Handbook
第21题:
Metro/Global Mirror
Metro Mirror
Global Copy
Global Mirror
第22题:
DS Hardware Management Console (HMC), because it manages ESS 800, DS6000, DS8000, and SVC storage servers
Tivoli Storage Productivity Center for Data, because it manages ESS 800, DS6000, DS8000, and SVC storage servers
Tivoli Storage Productivity Center for Replication, because it manages ESS 800, DS6000, DS8000, and SVC storage servers
External DS Hardware Management Console (HMC), because it manages ESS 800, DS6000, DS8000, and SVC storage servers
第23题:
DS8800 system with three frames
DS8800 system with one frame
DS8700 system with two frames
DS8800 system with two frames
第24题:
Customer Engineer
Storage Sales Specialist
Competeline Representative
Field Technical Storage Specialist (pre-sales)