An HMC is required for dual VIO servers.
Dual VIO servers require a split backplane.
A dual VIO enablement code must be entered from the ASMI interface.
The second VIO server must be created using the IVM command line interface.
第1题:
What restrictions apply to using virtual Ethernet within a cluster containing VIO clients?()
第2题:
Which of the following is a situation where dual (redundant) HMCs are recommended()?
第3题:
A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()
第4题:
A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()
第5题:
A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()
第6题:
When configuring dual VIO servers to connect to SAN based disk in failover mode, what setting must be applied? ()
第7题:
Purchase a second HMC and use this to manage the new servers.
Connect all of the new servers to the existing private HMC network.
Configure a second private network on their existing HMC for the new servers.
Connect 9 of the new servers to the existing HMC and use Integrated Virtualization Manager on the 10th.
第8题:
A VIO server requires a dedicated LHEA port.
There is a limit of 32 LPARs per virtual LAN.
Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.
Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.
第9题:
Implement PowerHA SystemMirror on both VIO servers.
Configure Etherchannel between the client LPARs and the two VIO servers
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第10题:
NPIV
vSCSI
Arbitrated loop
Converged adapter
第11题:
algorithm = failover
algorithm = round_robin
reserve_policy = no_reserve
reserve_policy = single_path
第12题:
When managing more than four VIO servers.
When installed with Power 570 and larger hardware.
When hosting both Linux and AIX on the same physical hardware.
When unexpected outage on a single HMC would prove an untenable risk for the hosted LPARs.
第13题:
A proposed server architecture includes SAN LUNs being presented to client LPARs using shared HBAs to reduce infrastructure cost. The customer requires minimal management efforts for the dual VIO Servers. Which technology is recommended for this proposal?()
第14题:
A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()
第15题:
A customer is buying 10 new Power 720 servers and will integrate them into their existing data center which also has two Power 595s and five Power 750s, taking the total number of systems to 17. All currently installed systems are managed by a single HMC.All the machines will have dual VIO Servers for redundancy, and 10 client LPARs. How can they manage the new machines for the least cost?()
第16题:
What is an advantage of using an HMC rather than IVM for system management?()
第17题:
A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()
第18题:
IPAT via Aliasing must be used
IPAT via Replacement must be used
Resilience must be provided by the use of dual VIO servers
Hardware Address Takeover (HWAT) must be used to ensure a consistent virtual MAC address
第19题:
Implement PowerHA SystemMirror on both VIO servers.
Configure Etherchannel between the client LPARs and the two VIO servers.
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第20题:
ImplementPowerHA SystemMirror on both VIO servers.
ConfigureEtherchannel between the client LPARs and the two VIO servers
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第21题:
Support for a single VIO Server environment
Adapters can be dedicated or virtual for each LPAR environment
Interfaces with Systems Director to manage the Power Systems servers
Supports multiple Power Systems servers from a single point of control
第22题:
Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAs
Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.
Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.
Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.
第23题:
Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.
Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.
Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.
Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.
第24题:
An HMC is required for dual VIO servers.
Dual VIO servers require a split backplane.
A dual VIO enablement code must be entered from the ASMI interface.
The second VIO server must be created using the IVM command line interface.