niusouti.com

You are installing Windows 2000 Server on a new computer that has a hardware-based RAID array, a floppy disk drive, and a CD-ROM drive. The disk controller for the RAID array is not included on the current Hardware Compatibility List (HCL). You run Window

题目

You are installing Windows 2000 Server on a new computer that has a hardware-based RAID array, a floppy disk drive, and a CD-ROM drive. The disk controller for the RAID array is not included on the current Hardware Compatibility List (HCL). You run Windows 2000 Setup by starting the computer from the Windows 2000 Server CD-ROM.

When the computer restarts at the end of the text mode portion of Windows 2000 Setup, you receive the following STOP error: "INACCESSABLE_BOOT_DEVICE ".

Which two actions should you take to eliminate the STOP error? (Choose Two)

A. Modify the Boot.ini file.

B. Restart Windows 2000 Setup by using the Windows 2000 Server CD-ROM.

C. Select Safe Mode from the Windows 2000 boot menu.

D. Remove the Windows 2000 Server CD-ROM from the CD-ROM drive.

E. Install a driver for the RAID controller form. a floppy disk.

F. Use Device Manager to update the driver for the RAID controller.


相似考题
更多“You are installing Windows 2000 Server on a new computer that has a hardware-based RAID array, a floppy disk drive, and a CD-ROM drive. The disk controller for the RAID array is not included on the current Hardware Compatibility List (HCL). You run Window”相关问题
  • 第1题:

    You are the network administrator for Ezonexam. You are installing Windows 2000 Server on a new computer by using the Windows 2000 Server compact disk. The computer has five 18-GB hard disks Dick0, Disk1, Disk2, Disk3, and Disk4. The disks do not have any partitions defined.

    You want to use as much space on Disk0 as possible for the partition on which Windows 2000 Server is installed. You want the disk on which you install Windows 2000 Server to be fault tolerant. You also want as much disk space as possible across the other disks to be available for data storage and to be fault tolerant.

    What should you do? (Each correct answer presents part of the solution. Choose three)

    A. Install Windows 2000 Server on a 4-GB NTFS partition on Disk 0. Configure the five disks as dynamic disks.

    B. Install Windows 2000 Server on a 18-GB NTFS partition on Disk 0. Configure the five disks as dynamic disks.

    C. Create a RAID-5 volume using Disk2, Disk3, and Disk4.

    D. Create a stripped volume using Disk2, Disk3, and Disk4.

    E. Create a RAID-5 volume using all disks.

    F. Create a stripped volume using all disks.

    G. Select the volume on Disk0 and add a mirror using Disk1.


    正确答案:BCG
    B,C,G 解析:Explanation: RAID-5 volume is where data is written to 3 to 32 physical disks at the same rate, and is interlaced with parity to provide fault tolerance for a single disk failure. Good read performance; good utilization of disk capacity; expensive in terms of processor utilization and write performance as parity must be calculated during write operations.

    Only Windows 2000 supports dynamic storage. To support dynamic storage, a single partition is created that includes the entire disk. A disk that you initialize for dynamic storage is a dynamic disk. Dynamic disks are divided into volumes, which can consist of a portion or portions of one or more physical disks. A dynamic disk can contain simple volumes, spanned volumes, striped volumes (RAID-0), mirrored volumes (RAID-1), and striped with parity volumes (RAID-5). You create a dynamic disk by upgrading a basic disk. A Mirrored volume is where two disks contain identical copies of data. The only software RAID supported on the system volume. Good read and write performance; excellent fault tolerance; but costly in terms of disk utilization, because 50 percent of the volume's potential capacity is used for data redundancy.

    Incorrect answers:
    A: It is not necessary to install Windows 2000 Server on a 4-GB NTFS partition on Disk0. Disk0 consists of 18-GB.

    D: Striped volume is where data is written to 2 to 32 physical disks at the same rate. It offers maximum performance and capacity but no fault tolerance.

    E: The main disadvantage of a RAID-5 volume is that once a drive fails, system performance suffers until you rebuild the RAID-5 volume. This is because the parity information must be recalculated through memory to reconstruct the missing drive. If more than one drive fails, the RAID-5 volume becomes inaccessible. This does not bode well for fault tolerance as is required in this question.

    F: Striped volumes do not provide fault tolerance.

  • 第2题:

    You are installing Windows 2000 Server on a new computer that has a single 10-GB SCSI disk. The disk controller is not included on the current Hardware Compatibility List (HCL). You start the computer by using the Windows 2000 Server CD-ROM.

    When the computer restarts at the end of the text mode portion of Windows 2000 setup, you receive the following STOP error: "INACCESSIBLE_BOOT_DEVICE."

    Which two actions should you take to eliminate the STOP error? (Choose Two)

    A.Restart the Windows 2000 Setup by using the Windows 2000 Server CD-ROM.

    B.Select Safe Mode from the Windows 2000 boot menu.

    C.Remove the Windows 2000 Server CD-ROM from the CD-ROM drive.

    D.Install a driver for the SCSI controller from a floppy disk.

    E.Use Device Manager to update the driver for the SCSI controller.


    正确答案:AD
    解析:Explanation: To solve the problem posed in this scenario we must restart the Windows 2000 installation process and supply the correct SCSI driver. We cannot use Device Manager or Safe Mode at this stage since Windows 2000 is not installed yet. We must press F6 when Setup prompts us to do so. We must then press F6 again to supply the driver for a mass storage controller to the Windows 2000 Setup program.

    Incorrect answers:
    B: We cannot use Safe Mode at this stage, as Windows 2000 is not installed yet.

    C: We need to Windows 2000 Server CD-ROM to be able to perform. the install process.

    E: The Device Manager cannot be used at this stage since Windows 2000 is not installed yet.

  • 第3题:

    You are the network administrator for . You manage a Windows Server 2003 computer that functions as a file server.The data volume on the server is configured as a software RAID-5 array. One of disks that contain the data volume fails. You replace the failed disk. You start the Disk Management utility and view the status listed in the following table.You need to restore fault tolerance.Which two actions should you perform?() (Each correct answer presents part of thesolution. Choose two.)

    A. Create a striped set that includes Disk1 and Disk2.

    B. Initialize Disk3 and convert it to a dynamic disk.

    C. Reactivate the RAID-5 array volume.

    D. Repair the RAID-5 array volume to include Disk3.

    E. Initiailize Disk3 and configure it as a basic disk.

    F. Reactivate the missing disk.


    参考答案:B, D

  • 第4题:

    You plan to install Windows 7 on a computer that contains a single hard disk drive. The hard disk drive isconnected to a RAID controller. During the installation, you discover that the Windows 7 installation mediadoes not include the files required to install the RAID controller. You need ensure that you can installWindows 7 on the hard disk drive.  What should you do?()

    • A、Insert the Windows installation media and press F8 during the computer s power-on self test (POST).
    • B、Insert the Windows installation media and press F6 during the computer s power-on self test (POST).
    • C、Start the computer from the Windows installation media. From the Install Windows dialog box, click Load Driver.
    • D、Start the computer from the Windows installation media. From the Install Windows dialog box, click Drive options (advanced).

    正确答案:C

  • 第5题:

    A server has had a drive fail in its storage RAID set.  The administrator swaps the drive with a replacement and the RAID set does not automatically start to rebuild the replaced drive.  Which ofthe following utilities would MOST likely be used to initialize the rebuilding of the replace mentdrive?()

    • A、Net use
    • B、Array management
    • C、Fdisk
    • D、Disk Management Plug-in

    正确答案:B

  • 第6题:

    You have a computer that runs Windows XP professional. The computer contains one partition and a floppy disk drive. You connect a new USB drive. You need to back up the computer to meet the following requirements: Enable a complete recovery if the hard disk fails. Enable an automatic restore of the operating systems. Automatically recreate the partitions during a restore process. What should you do?()

    • A、From System Restore, create a system restore point.
    • B、From the System Tools menu, run the Files and Settings Transfer Wizard.
    • C、From Windows Backup, run the Automated System Recovery (ASR) Wizard. 
    • D、From Windows Backup, run the Backup Wizard, and then select Only backup the System State data. 

    正确答案:C

  • 第7题:

    You are the desktop administrator for Company.com’s sales department. Company.com’s network contains a RIS server.  You need to install Windows 2000 Professional on a computer that has a SCSI disk subsystem. You start the computer by using the Windows 2000 Professional CD-ROM, and you begin the installation. However, Setup reports that it cannot find any disk on which to install Windows 2000 Professional. You start the computer by using a RIS bootable floppy disk, and you receive the same result. What should you do?()

    • A、 Add an answer file to the root directory of the RIS bootable floppy disk.      Start the computer by using the RIS bootable floppy disk, and run Setup by using RIS. 
    • B、 Add the SCSI-controller driver to the root directory of the RIS bootable floppy disk.     Start the computer by using the RIS bootable floppy disk, and run Setup by using RIS. 
    • C、 Start the computer by using the Windows 2000 Professional CD-ROM, and run Setup.     After Setup starts, provide an answer file on a floppy disk. 
    • D、 Start the computer by using the Windows 2000 Professional CD-ROM, and run Setup.     After Setup starts, provide a SCSI-controller driver on a floppy disk. 
    • E、 Start the computer by using the Windows 2000 Professional CD-ROM, and run Setup.     After Setup starts, provide the appropriate HAL on a floppy disk. 

    正确答案:D

  • 第8题:

    You plan to deploy a distributed database application that runs on multiple Windows Server 2008 R2  servers.   You need to design a storage strategy that meets the following requirements: èAllocates storage to servers as required  èUses the existing network infrastructure èUses standard Windows management tools   èEnsures that data is available if a single disk fails What should you include in your design?()

    • A、An iSCSI disk storage subsystem that supports Microsoft Multipath I/O. Configure the storage  subsystem as a RAID?0 array.
    • B、An iSCSI disk storage subsystem that supports Virtual Disk Service (VDS). Configure the storageubsystem as a RAID?5 array.
    • C、A Fibre Channel (FC) disk storage subsystem that supports Microsoft Multipath I/O. Configure the  storage subsystem as a RAID?0 array.
    • D、A Fibre Channel(FC)disk storage subsystem that supports the Virtual Disk Service(VDS).Configure  the storage subsystem as a RAID?5 array.

    正确答案:C

  • 第9题:

    You are the network administrator for You manage a Windows 2003 computer named TestKing3 that functions as a file server. The data volume on TestKing3 is configured as a software RAID-5 array. One of the disks that contains the data volume fails. You discover that the failure was caused by a faulty SCSI cable. You replace the SCSI cable. You need to restore the data volume to its previous state. You want to achieve this goal by using the minimum amount of administrative effort. What should you do?()

    • A、Run the diskpart active command on the failed volume
    • B、Select any volume in the RAID-5 array and reactivate the volume.
    • C、Import the disk that contains the failed volume.
    • D、Run the chkdsk /f command on the drive letter that represents the RAID-5 array.

    正确答案:B

  • 第10题:

    You administer a SQL Server 2008 instance. You plan to deploy a new database that has the following capacity requirements: 275 GB for the database data file; 50 GB for the transaction log file. The storage array has six 100-GB disk drives available for the database. The disks are attached to a redundant array of independent disks (RAID) controller that supports RAID levels 0, 1, 5, and 10. The write performance of the transaction log needs to be maximized. The database and transaction log files must be protected in the event of a drive failure. You need to design the storage system. Which storage configuration should you use?()

    • A、A single RAID 5 volume
    • B、A single RAID 10 volume
    • C、A RAID 0 volume and a RAID 5 volume
    • D、A RAID 1 volume and a RAID 5 volume

    正确答案:D

  • 第11题:

    单选题
    A disk drive failed in a RAID 5 array.  After replacing the disk drive, users are still reporting that access to the server is very slow.  Which of the following BEST explains the problem?()
    A

    The array is rebuilding.

    B

    The array must be reconfigured.

    C

    The array is corrupt.

    D

    The disk drive is not compatible.


    正确答案: D
    解析: 暂无解析

  • 第12题:

    单选题
    You plan to deploy a distributed database application that runs on Windows Server 2008 R2. You need to design a storage strategy that meets the following requirements: èAllocates storage to servers as required   èIsolates storage traffic from the existing network   èEnsures that data is available if a single disk fails   èEnsures that data is available if a single storage controller fails What should you include in your design?()
    A

    An iSCSI disk storage subsystem that uses Microsoft Multipath I/O. Configure a RAID?0 array.

    B

    An iSCSI disk storage subsystem that uses Virtual Disk Service (VDS). Configure a RAID?5 array.

    C

    A Fibre Channel (FC) disk storage subsystem that uses Microsoft Multipath I/O. Configure a RAID?5  array.

    D

    A Fibre Channel(FC)disk storage subsystem that uses Virtual Disk Service(VDS).Configure a RAID?0 array.


    正确答案: D
    解析: 暂无解析

  • 第13题:

    You are preparing to install Windows 2000 Server on a new computer. The computer is connected to a network that includes Windows 98 computers and Windows 2000 Server computers.

    You want to install Windows 2000 Server from source files that are located on a server on the network.

    What should you do?

    A.Start the new computer by using a Windows 98 network boot disk. Connect to the network server. Run Winnt32.exe.

    B.Start the new computer by using Windows 98 network boot disk. Connect to the network server. Run Winnt.exe.

    C.On a Windows 2000 Server computer, use Makebt32.exe to create installation startup disk. Start the new computer by using the first disk.

    D.On a Windows 2000 computer, format a floppy disk. Copy NTLDR, boot.ini, Ntdetect.com, Ntbootdd.sys to this disk. Start the new computer by using the disk.


    正确答案:B
    解析:Explanation: To install Windows 2000 Server on a computer from source files that are located in a centralized network location we would have to create a network boot disk that includes DOS drivers for the network adapter. We would have to start the computer using this boot disk and connect to the network share where the source files are located. Finally we would start installation process by using winnt.exe. We must use winnt.exe and not winnt32.exe as the boot disks operate in DOS mode, which works with 16-bit applications. We would thus not be able to use 32-bit applications like winnt32.exe.

    Incorrect answers:
    A: We must use winnt.exe and not winnt32.exe as the boot disks operate in DOS mode, which works with 16-bit applications. We would thus not be able to use 32-bit applications like winnt32.exe.

    C: Makebt32.exe is used to make Windows 2000 setup floppy disks. These cannot be used to connect to a network share.

    D: The boot disk must include drivers for the network adapter.

  • 第14题:

    You are the network administrator for Ezonexam.com.

    You need to upgrade a computer from Windows NT Server 4.0 to Windows 2000 server. The server has dual processors, 2 GB of RAM, a RAID controller with five SCSI hard disks in an array, and a generic 10/100-MB network adapter. You begin the installation of the Windows 2000 Server operating system.

    During the text portion of the installation, you receive the following error message:

    "Stop 0x00000078 Inaccessible_boot_device."

    You want to successfully upgrade the computer.

    What should you do? (Each answer presents part of the solution. Choose two)

    A.Start the computer by using a DOS disk and run FDISK.

    B.Update the firmware on the RAID controller.

    C.Restart the installation. During the text-mode setup-mode setup, press F6.

    D.Restart the installation. During the text-mode setup, create a new partition.

    E.Insert a floppy disk containing the OEM SCSI driver and specify the additional driver.


    正确答案:CE
    解析:Explanation:Assoonasyourmachinebootsintothetext-basedportionofSetup,youmaynoticeapromptatthebottomofthescreenthattellsyoutopressF6ifyouneedtoinstalladditionalSCSIorRAIDdrivers.Ifyoudon'twanttheseadditionaldrivers,justwaitafewsecondsanditwillgoaway.ButifyoursystemhasaSCSIorRAIDcontrollerthatyouknowisn'tgoingtoinitializewithoutanOEM-provideddriver,you'llneedtowatchthispartofSetupcloselyandhitF6.You'llneedtopressF6atthePressF6prompttoinstallSCSIdrivers.ThiswillletyouaccessyourSCSIharddrivesorCD-ROMsthatrequireadriver.Incorrectanswers:A:Thisissimilartocreatingapartition.Thereisnoneedtocreateanewpartition.Thiswillnotupgradethecomputersuccessfully.B:Thisisnotrequired.UpdatingfirmwareontheRAIDcontrollerwillnotenableyoutosuccessfullyupgradethecomputerinthiscase.D:Thereisnoneedtocreateanewpartition,youshouldpressF6whichwillallowyoutosuccessfullyupgradethecomputerbyallowingaccesstotheharddrivesorfloppyorCD-ROMdrivesthatrequiresdrivers.

  • 第15题:

    After installing a new hard drive into a server for the purpose of mirroring the data from the first drive to the second one, the server displays an “operating system not found” error. Which of the following should the technician do to boot the server from the original drive?()

    • A、Replace the second drive with a hot swappable one.
    • B、Swap the drive boot order in the BIOS
    • C、Make the second disk active under the disk management tool.
    • D、Rebuild the array using the hardware RAID tool at boot.

    正确答案:B

  • 第16题:

    A Windows 2003 server has the operating system installed on a software RAID mirror. After a failure of one disk in the array the server will no longer boot up. The other drive is still functioning. Which of the following should be done to correct the issue? ()

    • A、 Edit the boot.ini file.
    • B、 Change to a hardware RAID solution.
    • C、 Recreate the array.
    • D、 Edit the active drive in the array.

    正确答案:A

  • 第17题:

    A disk drive failed in a RAID 5 array.  After replacing the disk drive, users are still reporting that access to the server is very slow.  Which of the following BEST explains the problem?()

    • A、The array is rebuilding.
    • B、The array must be reconfigured.
    • C、The array is corrupt.
    • D、The disk drive is not compatible.

    正确答案:A

  • 第18题:

    As the administrator of your Windows 2000 corporate network you need to install Windows 2000 Professional on 88 computers, and you would like to do it with the least amount of administrative effort.  You have 38 PXE-Compliant computers and 50 NON PXE-Compliant computers ready to go. You confirm that all 88 computers and their hardware are included on the current Windows 2000 hardware compatibility list (HCL).You create an RIS image and load it onto a Windows 2000 RIS Server. You then start the 88 computers. You find that the 38 PXE-Compliant computers connect fine to the RIS server, however the 50 NON PXE-Compliant computers cannot connect to the RIS server.  What should you do to resolve this problem?()

    • A、Run RBFG*EXE to create a Non-PXE-compliant startup disk.
    • B、Run RIPREP.*XE to create a non - PXE complaint startup disk.
    • C、Grant the ‘Everyone’ group NTFS Read permission for the RIS image.
    • D、Grant the Administrators group NTFS Read permission for the RIS image.

    正确答案:A

  • 第19题:

    You have an Exchange Server 2010 organization. You plan to deploy two new Mailbox servers.  Both Mailbox servers will be members of a database availability group (DAG). You need to recommend a hard-disk configuration for the new servers. Your recommendation must meet the following requirements:.Maximize write performance .Prevent a switchover if a single disk fails Which disk configuration should you recommend?()

    • A、RAID 0 array
    • B、RAID 1 array
    • C、RAID 5 array
    • D、RAID 10 array

    正确答案:D

  • 第20题:

    You are the desktop administrator for your company's sales department. The company's network contains a RIS server. You need to install Windows XP Professional on a computer that has a SCSI disk subsystem. You start the computer by using the Windows XP Professional CD-ROM, and you begin the installation. However, Setup reports that it cannot find any disks on which to install Windows XP Professional.  You start the computer by using a RIS bootable floppy disk, and you receive the same result. What should you do?()

    • A、Add an answer file to the root directory of the RIS bootable floppy disk. Start the computer by using the RIS bootable floppy disk, and run Setup by using RIS. 
    • B、Add the SCSI-controller driver to the root directory of the RIS bootable floppy disk. Start the computer by using the RIS bootable floppy disk, and run Setup by using RIS. 
    • C、Start the computer by using the Windows XP Professional CD-ROM, and run Setup. After Setup starts, provide an answer file on a floppy disk. 
    • D、Start the computer by using the Windows XP Professional CD-ROM, and run Setup. After Setup starts, provide a SCSI-controller driver on a floppy disk. 
    • E、Start the computer by using the Windows XP Professional CD-ROM, and run Setup. After Setup starts, provide the appropriate HAL on a floppy disk.

    正确答案:D

  • 第21题:

    You are the desktop administrator for your company. The company's network contains a RIS server, a DHCP server, and a DNS server. You need to install Windows XP Professional on a computer that does not have a CD-ROM drive. The computer has the following configuration: a Pentium III 1-GHz processor, a 5-GB hard disk, 128 MB of RAM, a modem in the first PCI slot ,an Ethernet card in the last ISA slot. You attempt to install Windows XP Professional on the computer by using a RIS bootable floppy disk. However, you are unable to connect to the RIS server. What should you do?() 

    • A、Move the Ethernet card to the first ISA slot. 
    • B、Remove the Ethernet card and replace it with an Ethernet card that is PXE compliant. 
    • C、Share the RIS image on the RIS server. Create a network bootable floppy disk. Insert the floppy disk, and install Windows XP Professional from the share. 
    • D、Place the NDIS network drivers in the root directory of the RIS bootable floppy disk. Use the floppy disk to connect to the RIS server. 

    正确答案:B

  • 第22题:

    单选题
    A Windows 2003 server has the operating system installed on a software RAID mirror. After a failure of one disk in the array the server will no longer boot up. The other drive is still functioning. Which of the following should be done to correct the issue? ()
    A

     Edit the boot.ini file.

    B

     Change to a hardware RAID solution.

    C

     Recreate the array.

    D

     Edit the active drive in the array.


    正确答案: C
    解析: 暂无解析

  • 第23题:

    单选题
    You are the network administrator for You manage a Windows 2003 computer named TestKing3 that functions as a file server. The data volume on TestKing3 is configured as a software RAID-5 array. One of the disks that contains the data volume fails. You discover that the failure was caused by a faulty SCSI cable. You replace the SCSI cable. You need to restore the data volume to its previous state. You want to achieve this goal by using the minimum amount of administrative effort. What should you do?()
    A

    Run the diskpart active command on the failed volume

    B

    Select any volume in the RAID-5 array and reactivate the volume.

    C

    Import the disk that contains the failed volume.

    D

    Run the chkdsk /f command on the drive letter that represents the RAID-5 array.


    正确答案: D
    解析: 暂无解析