U-size templates
Phase changers
Baffles
Molex connectors
第1题:
Which one of the following is not relevant to the others?()
第2题:
After a server has been installed into a rack, an administrator must ensure which of the following?()
第3题:
Which of the following ensures that air is passed through a server chassis correctly?()
第4题:
Which of the following ensures the MOST secure access to a server room?()
第5题:
Warm air flow is permitted through the front bezel
The system is labeled so that it can be identified
Verify the change control process can be implemented
Determine the correct power requirements
第6题:
Holding the valve open for a long period
Increasing the starting air pressure used
Opening the stating air valve quickly
Reducing the starting air valve size
第7题:
Low compression pressure and high exhaust temperature
Low firing pressure and high exhaust temperature
Low compression pressure and low exhaust temperature
Low firing pressure and low exhaust temperature
第8题:
BDC
TDC
BBDC
ATDC
第9题:
第10题:
Sea water is heated to boiling temperature while under a vacuum
Sea water is passed over heated plates in a thin film
Heated sea water is injected into a vacuum chamber
Sea water is forced through a heated eductor
第11题:
Fan
Heat sink
Shroud
Radiator
第12题:
refreshing the air
making person upset
adjusting the air humidity
adjusting the air temperature
第13题:
Which of the following allows a program or port through a software firewall?()
第14题:
Which of the following channels air flow through a server chassis?()
第15题:
Which of the following components channels air flow through a server chassis?()
第16题:
Exception
Pass-through
Port-forwarding
Punch-through
第17题:
starting air pressure too high
correct timing of starting air valves
three of the six starting valves stuck
the turning gear disengaged
第18题:
blow
clean
scavenge
purge
第19题:
ID card readers
Server rack doors
Biometric devices
Locked doors
第20题:
too low starting air pressure
main start valve closed
neither A nor B
A and B
第21题:
Excessive compression in the cylinder
A broken intake valve
A dirty inlet filter element
An improperly adjusted discharge valve
第22题:
A room thermostat activates an electric heater at each individual chilled air outlet when necessary
Varying the number of passes the air makes across the coils
Varying the temperature of the water through the coils
Varying the quantity of water flowing through the coils
第23题:
noise coming from that air starting valve
continuous operation of the starting air compressor
zero air pressure in the air starting system
overheated starting air pipe to the cylinder head
第24题:
students
shorter
bought
insanity