SMS
alog
fsck
bosboot
第1题:
A patch has been applied to the operating system. After rebooting, the system is hung. Which of the following commands should have been performed to prevent the system from hanging?()
第2题:
A system administrator decides to review the system error log after installing new hardware. Which of the following is the correct command to use?()
第3题:
A system administrator has added a new graphics card to the system and rebooted. The system pauses with C31 in the three-digit displays. Which of the following causes could be the reason for the hang?()
第4题:
A system administrator wants to perform some system maintenance. The AIX installation CD is in the CDROM drive, however the system will not boot from the CD. Which command will assist in determining if the CDROM drive is currently a bootable device?()
第5题:
An application is no longer required to start up automatically at system boot. Which of the following supported procedures would the administrator use to accomplish this()
第6题:
CPU
Memory
Paging space
Disk capacityX
第7题:
Edit the /etc/inittab and comment out the entry that starts the application by placing a at the beginning of the line.
Use the chitab command.
Use the rmitab command.
Edit the /etc/reboot file to remove the entry that starts the application.
第8题:
Boot in maintenance mode and use fsck to check hd5.
Boot in maintenance mode, access the rootvg and check the /etc/inittab for corruption.
Boot in maintenance mode, access the rootvg and rebuild the boot image using the bosboot command.
Boot in maintenance mode, and reset the root password.
第9题:
Run a bosboot -a command
Mirror the hd5 on the two disks
Set up another service mode bootlist
Check the disks using a lsvg -p rootvg command
第10题:
lscfg -l cd0 -v
bootlist -m service -o
bosboot -a -d /dev/cd0
chdev -l cd0 -a boot=yes
第11题:
lppchk, bosboot
lslpp -l, oslevel
installp -C, lppchk
bosboot, synclvodm
第12题:
Move the RAID adapter to another slot.
Perform a baseline of the system.
Contact the reseller of the adapter for a replacement card.
Check the RAID adapter’s manufacturer for the latest drivers.
第13题:
After mirroring rootvg, a system administrator wants to validate that the system will boot correctly. Which of the following tasks must be performed before changing the boot order?()
第14题:
A system administrator received the following message while trying to ssh to a server: connection timed out.The administrator pinged the server and had no response. The administrator then pinged the gateway, and was successful. Which tool could the administrator use next to isolate the problem?()
第15题:
A system administrator was able to boot a system from the AIX installation CDROM. The migration install was selected, but the process hung at 92% complete. The system administrator then rebooted the system, which subsequently hung at LED 552. Which of the following options is the most probable cause?()
第16题:
A user reports a corrupted boot logical volume. In order to recreate the contents of the boot logical volume which of the following procedures should the user be advised to perform?()
第17题:
During reboot, the system hangs with an LED 0554 message that means, "The boot device could not be opened or a read failed." Which of the following recovery procedures should be taken ()
第18题:
Verify all HBA settings.
Upgrade the blade firmware.
Upgrade the OS level HBA drivers.
Set the system to boot from the local disk.
第19题:
The ODM is corrupted.
There is a hardware failure.
The bosboot command failed.
Not enough space is available in the filesystems.
第20题:
route
traceroute
netstat -nr
broadcast ping
第21题:
startcondresp
filemon
lsfs
mount
第22题:
errpt
syslog
prtdiag
errlogger
第23题:
Reboot the system in normal mode.
Use the bosboot command to rebuild the boot image.
Restore the boot logical volume from a mksysb image.
Reboot the system into maintenance mode and run fsck on the boot logical volume.