The maximum pressure developed by a waste heat boiler is determined by the main engine exhaust ______.
A.gas composition
B.gas temperature
C.pressure
D.timing
第1题:
Control of evaporation
A separate means to prevent feed-water contamination
Power circulating pump
Super-heater
第2题:
possible
necessary
practicable
impracticable
第3题:
prevent engine back pressure at heavy loads
increase total engine efficiency at low loads
prevent boiler corrosion at low engine loads
improve engine fuel consumption at any load
第4题:
Ⅰ only
Ⅱ only
both Ⅰ and Ⅱ
neither Ⅰ nor Ⅱ
第5题:
bearing pressure in a four-stroke/cycle acting single diesel engine is continually reversed
bearing pressure in a two-stroke/cycle single acting diesel engine is continually reversed
the maximum bearing pressure is higher in a single acting two-stroke/cycle diesel engine
two-stoke/cycle diesel engines require more complicated lubrication piping
第6题:
space limitations prevent separately run pipes
the engines are small auxiliary units
they are arranged to prevent gas backflow to each engine
a waste heat boiler is installed
第7题:
the bad smoke
the smoky exhaust
the exhaust temperature
the peak pressure
第8题:
suction pressure regulator
thermostatic bypass valve
sea water temperature
water level in the expansion tank
第9题:
reduce engine exhaust noise
reduce engine back pressure
recover heat which otherwise would be lost
increase turbocharger efficiency
第10题:
decrease in maximum cylinder pressure
increase in ignition lag
decrease in fuel consumption per horsepower-hour
decrease in exhaust manifold pressure
第11题:
provide steam for emergency propulsion
provide steam for the turbo-generator
heat the waste water tanks
steam for warming engines
第12题:
air compressor
refrigeration compressor
vacuum pump
purifier
第13题:
to reduce heat stress
to reduce low temperature corrosion
to improve firing and starting performance
fuel saving
第14题:
bypass exhaust gas at high loads to prevent excessive back pressure
bypass a portion of the exhaust gas at peak loads for better efficiency
recycle exhaust gas to the turbocharger
minimize moisture condensation in the boiler gas passages at low loads
第15题:
testing for the mechanical load and the thermal load
inspecting thermal and mechanical condition of the engine
inspecting each system and exhaust temperature
testing for compress pressure and explosion pressure
第16题:
cyclone furnace boiler type
dry back boiler type
water-tube type
critical circulation boiler type
第17题:
gas composition
gas temperature
pressure
timing
第18题:
decrease the velocity of gases flowing past the tubes
increase the rate of heat transfer
reduce accumulations carbon deposits
direct the flow of gases
第19题:
an diesel oil heater
a waste heat boiler
a fresh water generator
all the above
第20题:
Combustion does not begin until the piston starts down on the power stroke
Maximum combustion pressure is reached before TDC
Turbulence in the cylinder causes a delay in ignition
Maximum cylinder firing pressure is not developed until the piston passes TDC
第21题:
the bearing had been overheated
water was present in the oil
the lube oil was not being properly filtered
the maximum allowable bearing pressure had been exceeded
第22题:
help preheat the air for the furnaces
help preheat the feedwater
protect economizer from excessive heat
prevent excessive furnace heat losses
第23题:
reduce engine exhaust noise
reduce engine back pressure
increase engine cycle efficiency
increase turbocharger efficiency